6-Parameter Patient Monitor for ICU/CCU /Bedside monitor

Type:First-Aid Devices
Brand Name:SUNMINDRAY
Model Number:700MP
Place of Origin:Jiangsu, China (Mainland)
Screen:12.1 inch TFT
PARAMETERS:NIBP,ECG,SPO2,TEMP,HR,ETCO2
Specifications
12.1”high resolution color TFT display
96 hours trend graphic data, 12-lead ECG analysis
Arrhythmia and S-T segment analysis
Anti-defibrillation, Anti-high frequency electrotome
Multi-language,easy operate,durable and stable
Calculation function of drug concentration
drug titration and hemodynamic status
Wired or wireless network
Three-level Audible and visible alarm,events recallable
Nurse Call function
AC/DC power supply, built-in high rechargeable capacity battery
Built in high speed thermoprinter with 12.5, 25, 50mm/sec
Recharge of the battery automatically at connection of the
device to the circuit and automatic switching to battery at circuit
failure without loss of all data and parameters
Chinese, English and Russian language interface
Standard configuration: Battery, ECG,RESP,NIBP,SPO2,PR,TEMP
Optional function: IBP,EtCO2
Concentration of anaesthesiological gases(optional)
Specification:
Dimension: 272(H) X 327(W) X 145(D) (mm)
Weight: 6.5Kgs (with battery)
Resolution: 800×600
Display: Amount of waveforms in display 5
Amount of numerical parameters displayed on display
not less than 5
Power Supply: 220V±101%, 50Hz, power cable with euro plug
ECG
Measuring range: Adult 0~300bpm
Neonate and pediatric 0~350bpm
Band width: 0.05Hz~100Hz
Accuracy: ±1%
Lead Type: 5-lead and 3-lead selectable
Lead selection: standard I,II,III; augmented limb lead
aVR, aVL, aVF;Chest lead V1~V6
Resolution: 1 bpm
Trend monitoring time:no less than 96 hours
ST-Segment analysis: -2.0 mV ~2.0mV; auto
Arrhythmia analysis: 13 kinds of Arrhythmia analysis
Recognition of
cardiostimulator impulses
Scanning speed: 12.5, 25, 50mm/Second
Gain selection: x1/2, x1, x2; auto
Protection: Withstand 4000 VAC/ 50Hz voltage
Voltage in isolation against
Defibrillation and electrosurgical
interference
ECG cable : adults, pediatric and neonate
Alarm Range: 15-350 bpm
ARR Alarm: Audible and visible alarm,
events recallable
Channels: Five
Manual choice of amplification
NIBP
Method: Automatic Oscillometric
Operation Model: manual, automatic, continuous
Auto measurement
time interval: Adjustable 1 /2 /3/4
/5/10/15/30/60/90/120/240/480 Min.
Measuring Unit: mmHg /kPa selectable
Measurement types: Systolic, Diastolic, Mean
Measuring Range: Adult: 10~270mmHg; optional 0-300mmhg
Pediatric:10~200mmHg
Neonate: 10~135mmHg
sp; pediatric 10~200mmHg
neonate 10-135mmHg
Cuff pressure range: 0~320mmHg
Cuff type: adult cuff (standard)
pediatric and neonatal cuff (optional)
Cuff inflation time: < 10 seconds
Cuff deflation time: <20 seconds
Alarm: the maximum and minimum value can be set freely according to your need which will be stored by system automatically.
TEMP
Measuring range: 0~ 50 oC ( 32~122oF )
Probe Type: body temperature probe (standard)
esophageal temperature probe and Rectal Temperature probe
Resolution: 0.1oC
Accuracy: ±0.1oC (without probe)
Alarm: the maximum and minimum value can be set freely according to your need which will be stored by system automatically.
SpO2
Display: SpO2 value display, PR chart display and PR waveform display
SpO2 measuring range: 0~100% for adults, pediatrics and neonates
Resolution: 1%
Accuracy: ±1% ( 70%~100%)
±2% (0%~69%)
PR measuring range: 0~255 bpm
PR accuracy: ±1 bpm
Sensor Type: adult finger clip SpO2 sensor (standard)
pediatric finger clip SpO2 sensor and neonatal wrap SpO2 sensor (optional)